BPA180DT-1RER-9C69-DL piston pump for Hyundai R320LC-7 |
|||||||||||
Product name:BPA180DT-1RER-9C69-DL piston pump for Hyundai R320LC-7 |
|||||||||||
Item: |
|||||||||||
Details: |
|||||||||||
BPA180DT-1RER-9C69-DL piston pump for Hyundai R320LC-7 How to order:
Kawasaki Piston pump maintenance
1, the relief valve pressure should not be too high, generally 1.25 times the rated pressure of the pump.
2. After the user buys back the oil pump, if it is not used in time, anti-rust oil shall be injected into the inside, and the exposed surface shall be coated with anti-rust grease, and then the oil mouth dust cover shall be covered.
3. Regularly check the oil performance, and replace and clean the oil tank in time if it fails to meet the specified requirements.
4, keep the oil temperature within 10 to 60 ℃, especially to avoid high temperature continuous operation, otherwise the pump will shorten the service life. Set up heater and cooling device when necessary.
5. Keep the normal oil level high. An oil level gauge should be installed in the tank for regular observation and refilling.
6, in order to correct the hydraulic oil, it is necessary to know the oil tank operating temperature (open circuit) and the relationship between the environment temperature. Oil leakage (shell leakage) temperature is affected by the pump pressure and speed and always higher than the tank oil temperature. However, the temperature should not exceed 90 degrees anywhere in the system.
7. The oil filter should be cleaned frequently to ensure smooth oil suction.
8. After the oil pump works for a period of time, (due to vibration) mounting screws or inlet and outlet valve screws may become loose, please pay attention to check and tighten them to prevent loosening.
9. The hydraulic impact value of the system shall not exceed 14Mpa. |
|||||||||||